• Register

Please confirm that Sideral Tracking rate is 56096 with G11 and 448771 on M250-If correct how to reset the HC

+1 vote
asked May 1 by Aubrey (160 points)

1 Answer

+1 vote

Aubrey, 56096 is a divisor for Gemini-1. It will not work with Gemini-2. 448771 is the correct divisor for Gemini-2. If you need to reset it, just set the mount type to MI-250. This automatically resets the RA divisor to the correct one for your mount.

answered May 2 by paul_kanevsky (4,090 points)
Thanks, the documentation on this subject is sparse so it is great that you guys keep us all informed.

Aubrey
...